Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
21 September 2021 to 27 October 2021
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
OECD 102, GLP.
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Version / remarks:
1995
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
differential scanning calorimetry
Specific details on test material used for the study:
TEST MATERIAL:
- Name of test material: VISIOMER IBOA TG
- Chemical name: Isobornyl acrylate
- CAS: 5888-33-5
- Appearance: Clear colourless liquid
- Storage conditions: Ambient temperature (10 °C to 30 °C), dark
Key result
Melting / freezing pt.:
-50 °C
Atm. press.:
ca. 1 013 hPa
Decomposition:
yes
Decomp. temp.:
ca. 140 °C
Remarks on result:
other: Isobornyl acrylate had no melting point above -50 °C at 1013 hPa

Melting point (DSC measurements)

Ident No.

Test item /

mg

Starting temperature /

°C

Final test temperature /

°C

Temperature range (melting) /

°C

Crucible

Observations after the measurement

39748

13.55

-50

25

--

Aluminium with a hole

Test item was unchanged,

no mass loss

39749

11.23

-50

25

--

Aluminium with a hole

Test item was unchanged,

no mass loss

39758

14.74

-50

500

--

Aluminium with a hole

Little black residue, mass loss: 98 %

39761

11.34

-50

220

--

Aluminium with a hole

Test item was unchanged,

mass loss: 1 %

Conclusions:
In a valid guideline study Isobornyl acrylate had no melting point above -50 °C at 1013 hPa measured by DSC according to European Commission Regulation (EC) No. 440/2008, A.1. as well as OECD 102 (1995), GLP. (ARTF, 2021)
 
There was no exact melting point detected for IBOA.
Decomposition started at approx. 140 °C.
Executive summary:

In a valid guideline study Isobornyl acrylate had no melting point above -50 °C at 1013 hPa measured by DSC according to European Commission Regulation (EC) No. 440/2008, A.1. as well as OECD 102 (1995), GLP. (ARTF, 2021)

 

There was no exact melting point detected for IBOA.

Decomposition started at approx. 140 °C.

NOTE: Any of data in this dataset are disseminated by the European Union on a right-to-know basis and this is not a publication in the same sense as a book or an article in a journal. The right of ownership in any part of this information is reserved by the data owner(s). The use of this information for any other, e.g. commercial purpose is strictly reserved to the data owners and those persons or legal entities having paid the respective access fee for the intended purpose.

Description of key information

Isobornyl acrylate had no melting point above -50 °C at 1013 hPa measured by DSC according to European Commission Regulation (EC) No. 440/2008, A.1. as well as

OECD 102 (1995), GLP. (ARTF, 2021)

 

There was no exact melting point detected for IBOA.

  

The EPI Suite calculation predicted melting point is not a realistic value as IBOA would be solid at room temperature, which it is not.

Key value for chemical safety assessment

Melting / freezing point at 101 325 Pa:
-50 °C

Additional information

Isobornyl acrylatehad no melting point above-50 °C at 1013 hPa measured by DSC according toEuropean Commission Regulation (EC) No. 440/2008, A.1. as well as

OECD 102 (1995), GLP. (ARTF, 2021)

 

There was no exact melting point detected for IBOA.