Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2014-01-17 to 2014-04-29
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7950 (Vapor Pressure)
Principles of method if other than guideline:
The vapour pressure of the test substance (PT) was determined by the isothermal thermogravimetric effusion method. The method is validated in the range 10E-08 to 1.0E+03 Pa using a set of five reference substances with known vapour pressures.
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: by loss of weight or by trapping vaporisate
Specific details on test material used for the study:
- Identification: Ethyl-(S)-2-hydroxypropionate
- Molecular formula: C5H10O3
- Batch: 1007002470
- Purity/composition: 98 %
- Test substance storage: At room temperature in the dark under nitrogen
- Stable under storage conditions until:2015-01-01 (expiry date)
Temp.:
ca. 25 °C
Vapour pressure:
ca. 870 Pa
Temp.:
ca. 25 °C
Vapour pressure:
ca. 6.5 mm Hg
Temp.:
ca. 20 °C
Vapour pressure:
ca. 3.9 mm Hg
Key result
Temp.:
ca. 20 °C
Vapour pressure:
ca. 510 Pa
Conclusions:
The isothermal TGA effusion method was applied for the determination of the vapour pressure of ethyl (S)-lactate. The vapour pressure of the test substance at 20 °C (293 K) was 510 Pa or 3.9 mm Hg, and at 25 °C (298 K) it was 870 Pa or 6.5 mm Hg, respectively.
Executive summary:

The vapour pressure of the test substance ethyl (S)-lactate was determined by the isothermal thermogravimetric effusion method (TGA). The test item was placed in an oven and consequently stepwise isothermal heated. The weight-loss of the test item was measured and the vapour pressure determined by comparison with reference substances. Each reference substance and the test item were measured in duplicate by TGA.

Endpoint:
vapour pressure
Type of information:
other: publication
Adequacy of study:
supporting study
Study period:
1998
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data
Principles of method if other than guideline:
Standard overview of vapour pressure values for lactate esters, based on company in-house data.
GLP compliance:
no
Temp.:
20 °C
Vapour pressure:
2.2 hPa
Conclusions:
The vapour pressure of ethyl (S)-lactate is 2.2 hPa at 20 °C.
Executive summary:

According to Clary, the vapour pressure of ethyl (S)-lactate has been determined to 2.2 hPa at 20 °C.

Description of key information

The isothermal TGA effusion method was applied for the determination of the vapour pressure of ethyl (S)-lactate. The vapour pressure of the test substance at 20 °C (293 K) was 510 Pa or 3.9 mm Hg, and at 25 °C (298 K) it was 870 Pa or 6.5 mm Hg, respectively.

Key value for chemical safety assessment

Vapour pressure:
510 Pa
at the temperature of:
20 °C

Additional information

The vapour pressure of the test substance ethyl (S)-lactate was determined by the isothermal thermogravimetric effusion method (TGA). The test item was placed in an oven and consequently stepwise isothermally heated. The weight-loss of the test item was measured and the vapour pressure determined by comparison with reference substances. Each reference substance and the test item were measured in duplicate by TGA.