Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2008-06-25
Reliability:
1 (reliable without restriction)
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to other study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 170 Dry Sieve Analysis of Water Dispersible Granules and CIPAC MT 169 Tap Density of Water Dispersible Granules
Deviations:
no
Principles of method if other than guideline:
NA
GLP compliance:
yes (incl. QA statement)
Type of distribution:
volumetric distribution

Test material

Constituent 1
Details on test material:
Batch no: 002FL08;

Results and discussion

Particle size
Percentile:
D50
Mean:
>= 250 - < 2 000 µm
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Particle size distribution at different passagesopen allclose all
No.:
#1
Size:
63 µm
Distribution:
0.1 %
No.:
#2
Size:
125 µm
Distribution:
1.4 %
No.:
#3
Size:
250 µm
Distribution:
14.7 %
No.:
#4
Size:
500 µm
Distribution:
67 %
No.:
#5
Size:
1 000 µm
Distribution:
15.7 %
No.:
#6
Size:
2 000 µm
Distribution:
0.1 %
No.:
#7
Size:
4 000 µm
Distribution:
0 %

Any other information on results incl. tables

NA

Applicant's summary and conclusion

Conclusions:
The particle size distribution of the AVE 5530 EVA-KET was found to be [250 µm; 2000 µm].