Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 265-745-8 | CAS number: 65405-77-8
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Flash point
Administrative data
Link to relevant study record(s)
- Endpoint:
- flash point of flammable liquids
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 30th November 2010
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Remarks:
- Study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of the relevant results. The study report was conclusive, done to a valid guideline and the study was conducted under GLP conditions.
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.9 (Flash-Point)
- Deviations:
- no
- Qualifier:
- equivalent or similar to guideline
- Guideline:
- ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
- Version / remarks:
- 2002
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- non-equilibrium method closed cup
- Remarks:
- Pensky-Martens
- Key result
- Flash point:
- 110 °C
- Atm. press.:
- 101.325 kPa
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- Under the conditions of the study, the flash point of hexenyl-3-cis salicylate was determined to be 110°C at 101.325 kPa.
- Executive summary:
In a GLP-compliant flash point study conducted in line with EU Method A.9 and ISO 2719:2002, the flash point of hexenyl-3-cis salicylate was determined by the Pensky-Martens closed cup method. The flash point of the substance was determined to be 110°C at 101.325 kPa.
Reference
The results of the main test are:
First determination: Flash point, corrected for atmospheric pressure: 109.5°C
Second determination: Flash point, corrected for atmospheric pressure: 110.5°C
Description of key information
Flash point was determined to be 110°C at 101.325 kPa; study conducted in accordance with EU A.9 and ISO 2719:2002; Kruetzer (2011a)
Key value for chemical safety assessment
- Flash point at 101 325 Pa:
- 110 °C
Additional information
In a GLP-compliant flash point study conducted in line with standardised guidelines, the flash point of (Z)-3-hexenyl salicylate was determined by the Pensky-Martens closed cup method. The flash point of the substance was determined to be 110°C at 101.325 kPa. As the study was performed to GLP and standardised guidelines, it was allocated a reliability score of 1 and considered to be the key study.
Supporting information is presented as company product specifications and a Safety Data Sheet allocated a reliability score of 4. The flash point is reported as >94 - 113ºC.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.