Registration Dossier

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012-01-23 - 2012-01-24
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
according to guideline
Guideline:
other: CIPAC method MT22 1994, reprinted 2007
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
capillary viscometer (static)
Specific details on test material used for the study:
- Name of test material (as cited in study report): Amine C8
- Substance type: Brown liquid
- Physical state: Liquid
- Analytical purity: No data
- Lot/batch No.: LL101008
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
121.398
Remarks on result:
other: Mean of 3 results
Key result
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
36.458
Remarks on result:
other: Mean of 3 results

Individual results at 20°C:

run 1: 121.289 cSt

run 2: 121.478 cSt

run 3: 121.427 cSt

Individual results at 40°C:

run 1: 36.459 cSt

run 2: 36.449 cSt

run 3: 36.468 cSt

Conclusions:
The kinematic viscosity of the substance was determined to be 121.398 cSt of mm²/s (mean of 3 results) at 20°C.

Description of key information

The kinematic viscosity of the test substance was determined in a GLP study according to CIPAC test method MT 22 to be 121.398 cSt at 20 °C, applying a capillary viscometer (Younis, 2012).

Key value for chemical safety assessment

Viscosity:
121.398 mm²/s (static)
at the temperature of:
20 °C

Additional information

The kinematic viscosity at 40 °C was determined to be 36.458 cSt.