Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Justification for type of information:
Experimental tests performed using standard test guuidelines
Qualifier:
according to guideline
Guideline:
other: as mentioned below
Principles of method if other than guideline:
Lowest temperature determined at which substance vaporizes to form an ignitable mixture in air
GLP compliance:
no
Key result
Remarks on result:
other: Test chemical did not catch fire on being exposed to air at room temperature of 23 °C and atmospheric pressure of 955 hPa
Conclusions:
Test chemical did not catch fire on being exposed to air at room temperature of 23 °C and atmospheric pressure of 955 hPa. This indicates that test was not auto-flammable.
Executive summary:

Test chemical did not catch fire on being exposed to air at room temperature of 23 °C and atmospheric pressure of 955 hPa. This indicates that test was not auto-flammable.

Description of key information

Test chemical did not catch fire on being exposed to air at room temperature of 23 °C and atmospheric pressure of 955 hPa. This indicates that test was not auto-flammable.

Key value for chemical safety assessment

Additional information

Test chemical did not catch fire on being exposed to air at room temperature of 23 °C and atmospheric pressure of 955 hPa. This indicates that test was not auto-flammable.