Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

The flash point determination of test substance (CAS No. 6786 -83 -0) was done as per the test guideline OECD 103. The method is closed cup method using Pensky Martin’s Flash Point Apparatus. The flash point ofSolvent Blue 4(CAS No.6786-83-0) is experimentally determined to be greater than 285°C at 980.2hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
285 °C

Additional information

The flash point determination of test substance (CAS No. 6786 -83 -0) was done as per the test guideline OECD 103. The method is closed cup method using Pensky Martin’s Flash Point Apparatus.The flash point ofSolvent Blue 4(CAS No.6786-83-0) is experimentally determined to be greater than 285°C at 980.2hPa. The supporting study shows low value of flash point. For the purpose of chemical safety assessment, the flash point value of the key study has been considered.