Registration Dossier

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Based on the results of the test it is concluded that the substance is not a flammable gas.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

The flammability of the substance was determined in a study in accordance with EU Method A.11 (flammable gases) and in compliance with GLP criteria (NOTOX BV, 2010). At room temperature, up to a concentration of 20 % (v/v) small localized ignitions were observed but the flame never detached from the ignition source nor did it propogate.

Justification for classification or non-classification

The substance was found to be non-flammable in a test according to EU method A.11. Therefore, classification according to the CLP Regulation (EC) No 1272/2008 and the Dangerous Substance Directive 67/548/EC is not warranted.