Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 264-496-2 | CAS number: 63817-40-3
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
- General advice:
Call a physician if symptoms develop or persist.
- Following inhalation:
Supply fresh air; consult doctor in case of complaints.
- Following skin contact:
Remove contaminated clothing and wash affected skin with water and soap. If symptoms persist, consult a doctor.
- Following eye contact:
Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
- Following ingestion:
Rinse the mouth with plenty of water. If symptoms persist consult doctor.
- Most important symptoms and effects: No further relevant information available.
Fire-fighting measures
- Suitable extinguishing media:
Use fire extinguishing methods suitable to surrounding conditions. Extinguish with carbon dioxide, dry chemical, waterspray or foam.
- Unsuitable extinguishing media:
Do not use water jet as an extinguisher, as this will spread the fire.
- Special hazards arising from the substance or mixture:
In case of fire, the following can be released: Nitrogen oxides (NOx)
- Advice for fire fighter: Evacuate area and fight fire from a safe distance.
Protective equipment:
Fire fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.
Accidental release measures
- Personal precautions:
Provide sufficient air flow.
- Protective equipment and emergency procedures:
Wear protective equipment. Keep unprotected persons away. Use personal protective equipment
- Environmental precautions:
Do not allow to enter sewers/ surface or ground water.
- Methods and material for containment and cleaning up: For small spills add absorbent (soil may be used in the absence of other suitable materials) scoop up
material and place in a sealed, liquid-proof container for disposal. For large spills dike spilled material or otherwise contain material to ensure runoff does not reach a waterway. Place spilled material in an appropriate container for disposal.
Handling and storage
- Precautions for safe handling:
Intermediate to be used under strictly controlled conditions according to REACH-Regulation (EC) No 1907/2006 (Article 18)
Provide sufficient air flow/ air extraction in the workplace.
Avoid contact with eyes and skin.
- Conditions for safe storage, including any incompatibilities:
Keep tightly closed in a dry, cool and well-ventilated place. Store only in the original receptacle.
Store away from foodstuffs.
Store in cool, dry conditions in well sealed receptacles.
Store container in a well-ventilated place.
Specific end use(s)
Intermediate to be used under strictly controlled conditions according to REACH-Regulation (EC) No 1907/2006 (Article 18)
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Control parameters
· Ingredients with limit values that require monitoring at the workplace: The product does not contain any relevant quantities of materials with critical values that have to be monitored at the workplace.
· Additional information: The lists that were valid during the creation were used as basis.
Exposure controls: Intermediate to be used under strictly controlled conditions according to REACH-Regulation (EC) No 1907/2006 (Article 18)
General protective and hygienic measures:
The usual precautionary measures are to be adhered to when handling chemicals.
Avoid contact with the eyes and skin.
Immediately remove all soiled and contaminated clothing
Wash hands before breaks and at the end of work.
Do not eat or drink while working.
Respiratory protection: Not necessary if room is well-ventilated.
Protection of hands:
Protective gloves
The glove material has to be impermeable and resistant to the product.
Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation
The protective gloves to be used must comply with the specification of EU directive 89/686/EC and the resultant standard EN374. The above given information is based on laboratory test in line with EN374.
The recommendation is only valid for the supplied product and the stated application. Special working conditions, like heat or mechanical strain, which deviate from the test conditions, can reduce the protective effect provided by the recommended glove.
Material of gloves
The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer.
Hand protection: Wear suitable protective gloves (e.g. Polychloroprene −CR ).
Recommendation: contaminated gloves should be disposed of.
Penetration time of glove material
The exact breaktrough time has to be found out by the manufacturer of the protective gloves and has to be observed.
The determined penetration times according to EN 374 part III are not performed under practical conditions. Therefore a maximum wearing time, which corresponds to 50% of the penetration time, is recommended.
Eye protection: Tightly sealed goggles EN 166
Body protection: Protective work clothing
Stability and reactivity
1. Reactivity: No further relevant information available.
2. Chemical stability: No decomposition if used according to specifications.
3. Possibility of hazardous reactions: No dangerous reactions known.
4. Conditions to avoid: No further relevant information available.
5. Incompatible materials: No further relevant information available.
6. Hazardous decomposition products: No dangerous decomposition products known. During thermal decomposition formation of: Nitrogen oxides (NOx)
Disposal considerations
Recommendation
Product residues and uncleaned empty containers should be packaged, sealed, labelled and disposed of or recycled according to relevant national and local regulations. Where large quantities are concerned, consult the supplier.
When uncleaned empty containers are passed on, the recipient must be warned of any possible hazard that may be caused by residues. For disposal within the EC, the appropriate code according to the European Waste List (EWL) should be used. It is among the tasks of the polluter to assign the waste to waste codes specific to industrial sectors and processes according to the European Waste List (EWL).
European waste catalogue
It is not possible to determine a waste code for this product in accordance with the European Waste Catalogue (EWC) since it is only possible to classify it according to how it is used by the customer.
The waste code is to be determined within the EU in liaison with the wastedisposal operator.
Recommendation:
Packagings that may not be cleansed are to be disposed of in the same manner as the product.
Disposal must be made according to official regulations.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.