Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 217-982-3 | CAS number: 2031-62-1
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Eye irritation
Administrative data
- Endpoint:
- eye irritation: in vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 18 Feb - 23 Feb 2007
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 007
- Report date:
- 2007
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 405 (Acute Eye Irritation / Corrosion)
- Version / remarks:
- (2002)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method B.5 (Acute Toxicity: Eye Irritation / Corrosion)
- Version / remarks:
- (2002)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EPA OPPTS 870.2400 (Acute Eye Irritation)
- Version / remarks:
- (1998)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- Bayerisches Landesamt fuer Arbeitsschutz, Arbeitsmedizin und Sicherheitstechnik, Munich, Germany
Test material
- Reference substance name:
- Diethoxy(methyl)silane
- EC Number:
- 217-982-3
- EC Name:
- Diethoxy(methyl)silane
- Cas Number:
- 2031-62-1
- Molecular formula:
- C5H14O2Si
- IUPAC Name:
- diethoxy(methyl)silane
- Details on test material:
- - Name of test material (as cited in study report): Diethoxymethylsilane, SEMICOSIL M2E, Silane, diethoxymethyl-
- Physical state: colourless liquid
- Expiration date of the lot/batch: 12 January, 2008
- Storage condition of test material: at room temperature, protected from light and humidity
Constituent 1
Test animals / tissue source
- Species:
- rabbit
- Strain:
- New Zealand White
- Details on test animals or tissues and environmental conditions:
- TEST ANIMALS
- Source: Harlan Winkelmann GmbH, Borchen
- Weight at study initiation: animal #1: 3.2 kg, #2: 3.3 kg, #3: 3.4 kg
- Housing: in ABS-Plastic rabbit cages, floor 4200 cm²
- Diet: Altromin 2123 maintenance diet for rabbit, rich in crude fibre, totally pathogen free (TPF), ad libitum
- Water: tap water (drinking water, municipal residue control, microbiol. controlled periodically), ad libitum
- Acclimation period: at least 5 days
ENVIRONMENTAL CONDITIONS
- Temperature (°C): 18±3
- Humidity (%): 55±10
- Air changes (per hr): 10
- Photoperiod (hrs dark / hrs light): 12/12
Test system
- Vehicle:
- unchanged (no vehicle)
- Controls:
- other: the untreated eye served as control
- Amount / concentration applied:
- TEST MATERIAL
- Amount(s) applied (volume or weight with unit): 0.1 mL - Duration of treatment / exposure:
- 72 hours
- Observation period (in vivo):
- 72 hours
reading time points: 1, 24, 48 and 72 hours - Number of animals or in vitro replicates:
- 3 females
- Details on study design:
- SCORING SYSTEM: Draize scoring system
TOOL USED TO ASSESS SCORE: fluorescein
Results and discussion
In vivo
Resultsopen allclose all
- Irritation parameter:
- cornea opacity score
- Basis:
- mean
- Remarks:
- over all three animals
- Time point:
- 24/48/72 h
- Score:
- 0
- Max. score:
- 4
- Reversibility:
- other: not applicable
- Irritation parameter:
- iris score
- Basis:
- mean
- Remarks:
- over all three animals
- Time point:
- 24/48/72 h
- Score:
- 0
- Max. score:
- 2
- Reversibility:
- other: not applicable
- Irritation parameter:
- conjunctivae score
- Basis:
- mean
- Remarks:
- over all three animals
- Time point:
- 24/48/72 h
- Score:
- 0.11
- Max. score:
- 3
- Reversibility:
- fully reversible within: 72 hours
- Irritation parameter:
- chemosis score
- Basis:
- mean
- Remarks:
- over all three animals
- Time point:
- 24/48/72 h
- Score:
- 0
- Max. score:
- 4
- Reversibility:
- other: not applicable
- Irritant / corrosive response data:
- Animal No. 1 and 3 showed redness grade 1 of the conjunctivae 1 hour post instillation. 24 hours post instillation until the end of the observation period no signs of irritation were recorded.
Animal No. 2 showed redness grade 1 of the conjunctivae 1 hour, as well as 24 hours post instillation. 48 hours, as well as 72 hours post instillation no signs of irritation were recorded. - Other effects:
- Throughout the observation period no weight loss was observed for the test animals.
Applicant's summary and conclusion
- Interpretation of results:
- other: CLP/EU GHS criteria are not met, no classification required according to Regulations (EC) No 1272/2008.
- Conclusions:
- In conclusion, under the conditions chosen for the present study (according to OECD 405 and GLP) the test substance did not show eye irritating potential. Only one animal showed a slight redness of the conjunctivae which was fully reversed after 48 hours. Therefore, the stest substane does not need to be classified for eye irritation.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.