Registration Dossier

Administrative data

Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: testing method performed according to OECD107

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2014
Report Date:
2014

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 107 (Partition Coefficient (n-octanol / water), Shake Flask Method)
GLP compliance:
not specified
Type of method:
shake-flask method to: flask method
Partition coefficient type:
octanol-water

Test material

Reference
Name:
Unnamed
Type:
Constituent

Study design

Analytical method:
photometric method

Results and discussion

Partition coefficient
Type:
log Pow
Partition coefficient:
-0.83
Temp.:
23 °C
pH:
>= 2.6 - <= 2.7

Applicant's summary and conclusion

Conclusions:
Due to the partition coefficient n-octanol-water bioaccumulation is not expected.