Registration Dossier

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009-07-30
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Method : ISO 3219 which correspond to OEDC 114 Acceptable, well-documented technique which meets scientific principles

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009

Materials and methods

Test guideline
Qualifier:
equivalent or similar to
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
GLP compliance:
no
Type of method:
other: rheometer with concentric cylinders

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): Capa® Monomer
- Substance type: organic
- Physical state: liquid
- Analytical purity: GC area% 99.8
- Lot/batch No.: WNI 5862 26/5/09
- Stability under test conditions: stable
- Storage condition of test material: room temperature

Results and discussion

Viscosityopen allclose all
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
6.5
Temp.:
40°C
Parameter:
dynamic viscosity (in mPa s)
Value:
4

Applicant's summary and conclusion

Conclusions:
Viscosity: 6.5 mPa s at 20 °C; 4.0 mPa s at 40 °C
Executive summary:

Viscosity: 6.5 mPa s at 20 °C; 4.0 mPa s at 40 °C