Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009

Materials and methods

Test guideline
Qualifier:
equivalent or similar to
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
ASTM D 7094-04
Principles of method if other than guideline:
The method ASTM D 7094-04 is equal to ASTM D 93 according to note 6 in ASTM D 7094-04.
GLP compliance:
no
Type of method:
closed cup
Remarks:
Pensky Martin

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): Capa® Monomer
- Substance type: organic
- Physical state: liquid
- Analytical purity: GC area% 99.8
- Lot/batch No.: WNI 5862 26/5/09
- Stability under test conditions: stable
- Storage condition of test material: room temperature

Results and discussion

Flash point
Flash point:
111 °C
Atm. press.:
101.3 kPa

Applicant's summary and conclusion

Conclusions:
Flash point: 384 K (111 ºC)
Executive summary:

Flash point: 284 K (111 °C)