Registration Dossier

Administrative data

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: guidance followed, no GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report Date:
2009

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
ISO No., other: CSN EN ISO 2592/2002
Deviations:
no
Principles of method if other than guideline:
Cleveland open cup measuring according CSN EN ISO 2592/2002
GLP compliance:
no
Type of method:
non-equilibrium method open cup

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Flash point
Flash point:
ca. 224 °C
Atm. press.:
ca. 101.325 kPa

Any other information on results incl. tables

Correction of flash point: according Tcorr. = Tatm.+ 0.25 . (101.3 - patm.)

Standard deviation: 0.0 °C

Average flash point: 224.0 °C at 101.325 kPa

Applicant's summary and conclusion