Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2007
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
- Name of test material (as cited in study report): REACh Composite Sample 7 (anthracene oil <50 ppm BaP)
Key result
Flash point:
140 °C
Atm. press.:
1 013 hPa
Remarks on result:
other: test material: CCSG composite sample 07, anthracene oil
Key result
Flash point:
> 100 °C
Atm. press.:
1 013 hPa
Remarks on result:
other: typical value for anthracene oil (other batches of anthracene oil < 50 ppm BaP)
Interpretation of results:
GHS criteria not met

Description of key information

Anthracene oil (CCSG composite sample 07) (anthracene oil with < 50 ppm BaP, AOL) was demonstrated to have a flash point of 140 °C. Values of > 100 °C are typical of distinct batches of anthracene oil.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
140 °C

Additional information