Administrative data

First-aid measures

General advice:
In the case of accident or if you feel unwell, seek medical advice immediately.
When symptoms persist or in all cases of doubt seek medical advice.

Protection of first-aiders:
First Aid responders should pay attention to self-protection, and use the recommended personal protective equipment when the potential for exposure exists.

If inhaled: If inhaled, remove to fresh air. Get medical attention if symptoms occur.

In case of skin contact: Wash with water and soap as a precaution; Get medical attention if symptoms occur.

In case of eye contact: In case of contact, flush eyes with water as a precaution; Get medical attention if irritation develops and persists.

If swallowed:
Never give anything by mouth to an unconscious person.
DO NOT induce vomiting.
Rinse mouth thoroughly with water.
Call a physician or poison control centre immediately.

Most important symptoms and effects, both acute and delayed
Risks: Harmful if swallowed.

Indication of any immediate medical attention and special treatment needed Treatment: Treat symptomatically and supportively.

Fire-fighting measures

Extinguishing media
Suitable extinguishing media:
Water spray
Foam
Carbon dioxide (CO2)
Dry chemical

Unsuitable extinguishing media: None known.

Special hazards arising from the substance or mixture
Specific hazards during fire-fighting: Exposure to combustion products may be a hazard to health.

Hazardous combustion products:
Potentially toxic fluorinated compounds
Hydrogen fluoride
Carbon dioxide (CO2)
Carbon monoxide
Other hazardous decomposition products may be formed.

Advice for firefighters
Special protective equipment for fire-fighters: In the event of fire, wear self-contained breathing apparatus. Use personal protective equipment.

Specific extinguishing methods:
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Use water spray to cool unopened containers.
Remove undamaged containers from fire area if it is safe to do so.
Evacuate area.

Accidental release measures

Personal precautions, protective equipment and emergency procedures
Personal precautions: Use personal protective equipment. Follow safe handling advice and personal protective equipment recommendations.


Environmental precautions:
Discharge into the environment must be avoided.
Prevent further leakage or spillage if safe to do so.
Retain and dispose of contaminated wash water.
Local authorities should be advised if significant spillages cannot be contained.

Methods and material for containment and cleaning up
Methods for cleaning up: Sweep up or vacuum up spillage and collect in suitable container for disposal. Local or national regulations may apply to releases and disposal of this material, as well as those materials and items employed in the clean-up of releases. You will need to determine which regulations are applicable.

Handling and storage

Precautions for safe handling
Technical measures: See engineering measures under EXPOSURE CONTROLS/PERSONAL PROTECTION section.

Local/Total ventilation: Use only with adequate ventilation.

Advice on safe handling:
When using do not eat, drink or smoke.
Keep container closed when not in use.
Handle in accordance with good industrial hygiene and safety practice, based on the results of the workplace exposure assessment.
Take care to prevent spills, waste and minimize release to the environment.

Hygiene measures: When using do not eat, drink or smoke. Wash contaminated clothing before re-use.

Conditions for safe storage, including any incompatibilities
Requirements for storage areas and containers: Keep in properly labelled containers. Store in accordance with the particular national regulations.

Advice on common storage: Do not store with the following product types: Strong oxidizing agents

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Exposure controls
Engineering measures. Ensure adequate ventilation, especially in confined areas. Minimize workplace exposure concentrations.

Personal protective equipment
Eye protection: Wear the following personal protective equipment: Safety glasses
Hand protection: Wash hands before breaks and at the end of workday.
Skin and body protection: Select appropriate protective clothing based on chemical resistance data and an assessment of the local exposure potential.
Respiratory protection: Use respiratory protection unless adequate local exhaust ventilation is provided or exposure assessment demonstrates that exposures are within recommended exposure guidelines. Filter type: Particulates type (P)

Stability and reactivity

Reactivity: Not classified as a reactivity hazard.

Chemical stability: Stable under normal conditions.

Hazardous reactions: Can react with strong oxidizing agents. Hazardous decomposition products will be formed at elevated temperatures.


Conditions to avoid: None known.

Incompatible materials
Materials to avoid: Oxidizing agents

Hazardous decomposition products
Thermal decomposition:
Potentially toxic fluorinated compounds
Hydrofluoric acid
Carbonyl difluoride
Carbon dioxide
Carbon monoxide

Disposal considerations

Waste treatment methods

Product: Dispose of in accordance with local regulations. According to the European Waste Catalogue, Waste Codes are not product specific, but application specific. Waste codes should be assigned by the user, preferably in discussion with the waste disposal authorities.