Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Endpoint summary

Administrative data

Description of key information

Hydrolysis: In accordance with column 2 of REACH Annex VIII, the study does not need to be conducted since the substance is readily biodegradable.

Biodegradation: Key study. Method according to OECD 301F / EU C.4 (Manometric respirometry), GLP study. At the 28th day of the test the measured aerobic biodegradation of the test item attained 74.8%. Thus, the test item can be deemed to be readily biodegradable.

Adsorption: In accordance with column 2 of REACH Annex VIII, the study does not need to be conducted if, based on the physicochemical properties, the substance can be expected to have a low potential for absorption. Nevertheless, the calculated Koc of the test item is 663.5 L/kg and log Koc is 2.822 ( EPI Suite, KOCWIN v2.00, MCI method).

Additional information