Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
other: Handbook data
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data
Remarks:
Handbook data considered to be from a trusted source acc. to "ECHA, Guidance on information requirements and chemical safety assessment – Chapter R.7a: Endpoint specific guidance".
Qualifier:
no guideline followed
Principles of method if other than guideline:
Not applicable - Handbook data
Type of method:
other: no data
Temp.:
594 °C
Vapour pressure:
1 Pa
Temp.:
686 °C
Vapour pressure:
10 Pa
Temp.:
803 °C
Vapour pressure:
100 Pa
Temp.:
959 °C
Vapour pressure:
1 kPa
Temp.:
1 177 °C
Vapour pressure:
10 kPa
Temp.:
1 503 °C
Vapour pressure:
100 kPa
Conclusions:
The vapour pressure of silver iodide is negligible at ambient temperatures:
1Pa at 594°C,
10 pa at 686°C,
100Pa at 803°C
1kPa at 959°C
10kPa at 1177°C and
100kPa at 1503°C

Description of key information

According to reliable secondary literature (factual handbook), the  vapour pressure of silver iodide increases with temperature: 1 Pa at 594°C, 10 Pa at 686°C, 100 Pa at 803°C, 1kPa at 959°C, 10kPa at 1177°C, 100kPa at 1503°C. By extrapolation, it can safely be assumed that the vapour pressure of AgI is negligible at ambient temperatures.

Key value for chemical safety assessment

Additional information