Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018-04-20
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 3104 (Petroleum products - Transparent and opaque liquids - Determination of kinematic viscosity and calculation of dynamic viscosity)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
capillary viscometer (static)
Specific details on test material used for the study:
- Batch No.of test material: 20141015
- Purity: 99.35%
- Expiration date of the lot/batch: January 2019
- Stability under test conditions: Room temperature
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
3.06
Remarks on result:
other: mean of 2 runs
Key result
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
2.004
Remarks on result:
other: mean of 2 runs

Full test results:

Run

Temp. (°C)

Size No

C

Time (sec)

Viscocity (cSt)

 

Tested @ 20°C

 

1

20

2

0.01094

280.28

3.066

2

20

2

0.01094

279.20

3.054

                                                              Tested@40°C                                     

1

40

1

0.003337

599.62

2.001

2

40

1

0.003337

601.69

2.008

Key: C = viscosity constant; Size no = size of viscometer

Conclusions:
The viscosity of the test item was determined to be 3.060 cSt at 20 °C and 2.004 cSt at 40°C.

Description of key information

The test conducted in accordance with ISO 3104:1994 and OECD Test Guideline 114 revealed a viscosity of 3.060 cSt at 20°C and 2.004 cSt at 40°C (K1, Dekra, 2018).

Key value for chemical safety assessment

Viscosity:
3.06 mm²/s (static)
at the temperature of:
20 °C

Additional information