Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)

Data source

Reference
Reference Type:
other: Body responsible for the test
Title:
Unnamed
Year:
2009

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Version / remarks:
2004
GLP compliance:
no
Type of method:
other: Rapid equilibrium closed cup method

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Flash point
Flash point:
> 200 °C
Atm. press.:
10 140 kPa

Applicant's summary and conclusion