EC number: 605-029-8 | CAS number: 155852-41-8
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
4.1 Description of first aid measures
General advice
: Remove/Take off immediately all contaminated clothing.
If inhaled
: If inhaled, remove to fresh air.
Get medical advice/ attention.
In case of skin contact
: In case of contact, immediately flush skin with plenty of wa-ter.
In case of eye contact
: In the case of contact with eyes, rinse immediately with plen-ty of water and seek medical advice.
If swallowed
: Call in a physician immediately and show him the Safety Data Sheet.
4.2 Most important symptoms and effects, both acute and delayed
Symptoms :
None known.
Risks :
None known.
4.3 Indication of any immediate medical attention and special treatment needed
Treatment
:
Treat symptomatically.
Fire-fighting measures
5.1 Extinguishing media
Suitable extinguishing media
: Carbon dioxide (CO2)
Water mist
Foam
5.2 Special hazards arising from the substance or mixture
Specific hazards during fire-fighting
: In case of fire hazardous decomposition products may be produced such as:
Carbon monoxide
Carbon dioxide (CO2)
5.3 Advice for firefighters
Special protective equipment for firefighters
: Self-contained breathing apparatus
Further information
: Cool endangered containers with water spray jet.
Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations.
Accidental release measures
6.1 Personal precautions, protective equipment and emergency procedures
Personal precautions
:
Wear suitable protective equipment.
Information regarding Safe handling, see chapter 7.
For personal protection see section 8.
Information regarding Waste Disposal, see chapter 13.
6.2 Environmental precautions
Environmental precautions
: Do not allow to enter drains or waterways
6.3 Methods and material for containment and cleaning up
Methods for cleaning up
: Soak up with inert absorbent material.
Can be landfilled or incinerated, when in compliance with local regulations.
6.4 Reference to other sections
For personal protection see section 8., For disposal considerations see section 13.
Handling and storage
7.1 Precautions for safe handling
Advice on safe handling
: Use only in well-ventilated areas.
Advice on protection against fire and explosion
: Observe the general rules of industrial fire protection
Hygiene measures
: Wash hands before breaks and at the end of workday.
Observe the usual precautions for handling chemicals.
7.2 Conditions for safe storage, including any incompatibilities
Requirements for storage areas and containers
: Keep only in the original container.
Keep container tightly closed.
Further information on stor-age conditions
: Keep containers tightly closed in a dry, cool and well-ventilated place.
Advice on common storage
: Avoid storage near incompatibile agents (see section 10).
Do not store or transport together with foodstuffs
Other data
: Shelf life is limited; see product information leaflet
7.3 Specific end use(s)
Specific use(s)
: No further recommendations.
Transport information
Land transport (UN RTDG/ADR/RID)
- UN number:
- Not regulated as a dangerous good
Shippingopen allclose all
SpecialProvisionsopen allclose all
Inland waterway transport (UN RTDG/ADN(R))
- UN number:
- Not regulated as a dangerous good
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
- UN number:
- Not regulated as a dangerous good
Shippingopen allclose all
Remarksopen allclose all
Air transport (UN RTDG/ICAO/IATA)
- UN number:
- Not regulated as a dangerous good
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all
Exposure controls / personal protection
8.1 Control parameters
No data available
Derived No Effect Level (DNEL) according to Regulation (EC) No. 1907/2006:
Substance name End Use Exposure routes Potential health ef-fects Value
Predicted No Effect Concentration (PNEC) according to Regulation (EC) No. 1907/2006:
Substance name Environmental Compartment Value
Benzofuranacetic acid, 2,3-dihydro-, methyl ester
Remarks:
No data available
8.2 Exposure controls
Engineering measures
See section 7; no measures in addition to the ones mentioned are necessary.
Personal protective equipment
Eye protection
: Safety glasses
Hand protection
Remarks
: Rubber gloves
Skin and body protection
: Protective suit
Respiratory protection : Use respiratory protection unless adequate local exhaust ventilation is provided or exposure assessment demonstrates that exposures are within recommended exposure guidelines.
Protective measures
: Avoid contact with skin and eyes.
Stability and reactivity
10.1 Reactivity
See section 10.3. "Possibility of hazardous reactions"
10.2 Chemical stability
Stable under normal conditions.
10.3 Possibility of hazardous reactions
Hazardous reactions
: No dangerous reaction known under conditions of normal use.
Stable
10.4 Conditions to avoid
Conditions to avoid
: None known.
10.5 Incompatible materials
Materials to avoid
: not known
10.6 Hazardous decomposition products
Carbon monoxide and carbon dioxide
Disposal considerations
13.1 Waste treatment methods
Product : Must be incinerated in a suitable incineration plant holding a permit delivered by the competent authorities.
Contaminated packaging : Packaging that cannot be cleaned should be disposed of as product waste
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.