Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Q2-Q3, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
-
Deviations:
no
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
Glycine, N-acetyl-N-[3-(trifluoromethyl)phenyl]valyl-, ethyl ester
EC Number:
609-496-9
Cas Number:
379685-94-6
Molecular formula:
C18H23F3N2O4
IUPAC Name:
Glycine, N-acetyl-N-[3-(trifluoromethyl)phenyl]valyl-, ethyl ester
Test material form:
solid: particulate/powder
Remarks:
Off white to beige powder with agglomerates
Specific details on test material used for the study:
- Analytical purity: 98.5% (HPLC)- Lot/batch No.: 0161045- Expiration date of the lot/batch: 2018/06/16

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
No ignition was observed throughout the course of the preliminary Screening-test. Therefore the test substance should be considered as not highly flammable (for EU regulations) and non-flammable solid (for UN regulations), resp.
Executive summary:

The flammability of the test substance was investigated with a not-GLP compliant study following the EU method A.10. No ignition was observed throughout the course of the preliminary Screening-test. Therefore the test substance should be considered as not highly flammable (for EU regulations) and non-flammable solid (for UN regulations), resp.