Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 433-470-4 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Endpoint summary
Administrative data
Description of key information
Additional information
Test substance is a Pale yellow crystalline solid at 20°C and 1013 hPa.
Melting Point: The melting temperature of SETAFIX 1077 was determined to be 85°C – 87°C (358K - 360K).
Boiling Point: Boiling point of the test substance was not observed. Reaction or decomposition of the test substance was observed above approximately 243°C (516K).
Density: The density of SETAFIX 1077 is 1.25g/cm³
Granulometry: The testing conducted to determine the Particle size analysis produced the following results:
Manual sieve analysis indicated that 43.5 % by weight of the sample had a particle size of < 850 μm.
A subsequent laser diffraction analysis on the < 850 μm sample produced the following results:
Average Volume %: 100.0
Mean (micrometres): 452.1
Median (micrometers): 509.2
Mode (micrometers): 859.9
95 % Conf. limit (micrometers): 160 -1270
S.D.: 1.7
< 10 % of material is 212.1 micrometers
< 25 % of material is 333.5 micrometers
< 50 % of material is 509.2 micrometers
< 75 % of material is 688.8 micrometers
< 90 % of material is 811.2 micrometers
Vapour Pressure: The value of the vapour pressure of SETAFIX 1077 at 20°C was determined to be: 0.019 (+/-0.3) Pa at 20°C.
Partition Coefficient Octanol/water: The Pow value for the major component in SETAFIX 1077 is 18000 (log Pow= 5.2) at 24.5 ± 0.5 °C.
Water Solubility: Water solubility of the substance was measured at 0.0000088g/L (< 0.10 mg/L)
Surface tension: According to COLUMN 2 Specific Rules For Adaptation From Column 1 set out in Section 7.6, Annex VII of REACH, if the water solubility is below 1.0 mg/L at 20°C the test does not need to be conducted.
The water solubility of the substance is below 1 mg/L, therefore it is not possible to satisfactorily measure the surface tension of the substance. Water solubility of the test substance is just 8.8 μg/L (8.8 x 1E-0·6 g/L) at 19.5 ± 1.0°C, so this study can be waived.
Flash point: According to General Rules For Adaptation of the Standard Testing Regime set out in Annexes VII to X (Section 2 of Annex XI of REACH) testing does not appear scientifically necessary. The flash point is only a relevant property for liquids, thus it does not need to be done for substances that are solids or gases at room temperature. The test substance is a solid at room temperature and therefore flash point is not justified in this case.
Auto Flammability: No self-ignition of the test substance was observed
Flammability:
Flammability test: Result is that the substance is considered "NOT highly Flammable" as the test substance failed to ignite under test conditions.
Pyrophoricity test: Substance does not contain groups that might lead to spontaneous ignition a short time after coming in contact with air at room temperature.
Flammability in contact with water test: Substance does not contain groups that might lead to evolution of highly flammable gases in dangerous quantities.
Explosiveness: SETAFIX 1077 is not an explosive.
Oxidising Properties: SETAFIX 1077 has no oxidising properties.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.