Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
141 °C
Atm. press.:
101.325 kPa
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test material was determined to be 141 °C under the conditions of the test.
Executive summary:

The flash point of the test material was determined using a method conducted in accordance with ASTM D93 using the Pensky-Martens closed cup procedure. Under the conditions of the test, the test material was determined to have a flash point of 141 °C.

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
14th January 1993 to 18th May 1994
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Flash point:
136.5 °C
Atm. press.:
101.325 kPa
Remarks on result:
no flash point up to 100°C

- Run 1 (range-finding):

Highest ‘no-flash temperature’ 125 °C

 Lowest ‘flash’ temperature 140 °C

- Run 2 (range-finding):

Highest ‘no-flash temperature’ 135 °C

 Lowest ‘flash’ temperature 137 °C

- Run 3 (definitive):

Highest ‘no-flash temperature’ 135 °C

 Lowest ‘flash’ temperature 136 °C

- Run 4 (definitive):

Highest ‘no-flash temperature’ 135 °C

 Lowest ‘flash’ temperature 136 °C

Mean flash point from two definitive runs: 136 °C

Atmospheric pressure 745.25 mm Hg = 99.358 kPa

Corrected flash point at 101.325 kPa : 136.5 °C

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test material was determined by a closed cup equilibrium method to be 136.5 °C at 101.325 kPa.
Executive summary:

The flash point of the test material was determined by a closed cup equilibrium method in accordance with EU Method A.9. The flash point of the test material was determined to be 136.5 °C at 101.325 kPa.

Description of key information

The flash point of the test material was determined using a method conducted in accordance with ASTM D93 using the Pensky-Martens closed cup procedure. Under the conditions of the test, the test material was determined to have a flash point of 141 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
141 °C

Additional information