Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
-Purity: Unknown or Variable composition, is a Complex reaction product, or a Biological material (UVCB)
-Description: Dark Green Liquid
-Storage: Room temerature (15 to 30°C)
Key result
Parameter:
other: Assessment has been based on the provided structural information only and information on the original materials used for preparation
Value:
17.69
Remarks on result:
negative (not further specified)
Interpretation of results:
GHS criteria not met
Conclusions:
The DSC analysis gave a small exotherm followed by a small endotherm, broadly similar to that in the melting point test. The exotherm had an onset temperature of 201.07°C and an energy of 17.69 J/g. This energy is well below 500 J/g so would suggest that the test substance does not show explosive properties. During the test fumes were evolved along with a burning odour. The test substance started as a dark green liquid and after the test the pan was found to have a blue/green substance on part of the surface. This substance is not explosive.
Executive summary:

The DSC analysis gave a small exotherm followed by a small endotherm, broadly similar to that in the melting point test. The exotherm had an onset temperature of 201.07°C and an energy of 17.69 J/g. This energy is well below 500 J/g so would suggest that the test substance does not show explosive properties. During the test fumes were evolved along with a burning odour. The test substance started as a dark green liquid and after the test the pan was found to have a blue/green substance on part of the surface. This substance is not explosive.

Description of key information

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Justification for classification or non-classification

The DSC analysis gave a small exotherm followed by a small endotherm, broadly similar to that in the melting point test. The exotherm had an onset temperature of 201.07°C and an energy of 17.69 J/g. This energy is well below 500 J/g so would suggest that the test substance does not show explosive properties. During the test fumes were evolved along with a burning odour. The test substance started as a dark green liquid and after the test the pan was found to have a blue/green substance on part of the surface. This substance is not explosive.