Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Skin irritation / corrosion

Currently viewing:

Administrative data

Endpoint:
skin corrosion: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15 - 16 Oct 2014
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions
Remarks:
only the 4-hour exposure period was assessed

Data source

Referenceopen allclose all

Reference Type:
study report
Title:
Unnamed
Year:
2014
Report date:
2014
Reference Type:
other: amendment
Title:
Unnamed
Year:
2014
Report date:
2014

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 431 (In Vitro Skin Corrosion: Human Skin Model Test)
Version / remarks:
adopted in 2013
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method B.40 (In Vitro Skin Corrosion: Transcutaneous Electrical Resistance Test (TER))
Version / remarks:
adopted in 2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Gyógyszerészeti és Egészségügyi Minőség- és Szervezetfejlesztési Intézet (National Institute for Quality- and Organizational Development in Healthcare and Medicines), Budapest, Hungary

Test material

Constituent 1
Chemical structure
Reference substance name:
2-[[(butylamino)carbonyl]oxy]ethyl acrylate
EC Number:
264-036-0
EC Name:
2-[[(butylamino)carbonyl]oxy]ethyl acrylate
Cas Number:
63225-53-6
Molecular formula:
C10H17NO4
IUPAC Name:
2-[[(butylamino)carbonyl]oxy]ethyl acrylate

In vitro test system

Test system:
human skin model
Source species:
human
Cell type:
non-transformed keratinocytes
Details on animal used as source of test system:
SOURCE
- Source: SKINETHIC Laboratories, Lyon, France
- Age: adult
Justification for test system used:
The EPISKIN model has been validated for corrosivity testing in an international trial; it is considered to be suitable for this study (Statement on the scientific validity of the EPISKINTM Test (an in vitro test for skin corrosivity); ECVAM JRC Environment Institute, European Commission; Ispra; 03 April 1998).
Vehicle:
unchanged (no vehicle)
Details on test system:
RECONSTRUCTED HUMAN EPIDERMIS (RHE) TISSUE
- Model used: EpiSkinTM Small Model (EpiSkinTMSM), EPISKIN SNC Lyon, France
- Tissue batch number(s): 14-EKIN-039

TEMPERATURE USED FOR TEST SYSTEM
- Temperature used during treatment / exposure: room temperature

REMOVAL OF TEST MATERIAL AND CONTROLS
-Volume and number of washing steps: 1 step
- Observable damage in the tissue due to washing: no; care was taken to avoid the damage of epidermis

MTT DYE USED TO MEASURE TISSUE VIABILITY AFTER TREATMENT / EXPOSURE
- MTT concentration: 0.3 mg/mL
- Incubation time: 3 h
- Spectrophotometer: yes
- Wavelength: 570 nm

NUMBER OF REPLICATE TISSUES: 2

NUMBER OF INDEPENDENT TEST SEQUENCES / EXPERIMENTS TO DERIVE FINAL PREDICTION: 1

PREDICTION MODEL / DECISION CRITERIA (choose relevant statement)
- The test substance is considered to be corrosive to skin if mean tissue viability is < 35% after 4 h exposure.
- The test substance is considered to be non-corrosive to skin if mean tissue viability ≥ 35% after 4 h exposure.
Control samples:
yes, concurrent negative control
yes, concurrent positive control
Amount/concentration applied:
TEST MATERIAL
- Amount(s) applied: 50 µL

NEGATIVE CONTROL
- Amount(s) applied: 50 µL
- Concentration (if solution): 9 g/L saline

POSITIVE CONTROL
- Amount(s) applied: 50 µL
- Concentration (if solution):
Duration of treatment / exposure:
4 h at RT
Number of replicates:
2

Results and discussion

In vitro

Results
Irritation / corrosion parameter:
% tissue viability
Value:
121
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Remarks on result:
no indication of irritation
Other effects / acceptance of results:
- OTHER EFFECTS:
- Direct-MTT reduction: No colour change was observed after 3 h of incubation during the check-test for possible direct MTT reduction with test item. The test item did not interact with the MTT, therefore additional controls and data calculations were not necessary. A false estimation of viability can be precluded.
- Colour interference with MTT: The intrinsic colour of the test item was found to be colourless in small amount (such as treatment volume) and showed no ability to become coloured in contact with water during the check-test to detect the colouring potential of test item, therefore additional controls and data calculations were not necessary. A false estimation of viability can be precluded.

ACCEPTANCE OF RESULTS:
- Acceptance criteria met for negative control: yes
- Acceptance criteria met for positive control: yes
- Acceptance criteria met for variability between replicate measurements: yes
- Range of historical values if different from the ones specified in the test guideline: Please refer to table 2.

Any other information on results incl. tables

Table 3. MTT assay after 4 h exposure.

 

Negative control

Positive control

Test item

Tissue sample

1

2

1

2

1

2

OD570

0.774

0.716

0.048

0.013

0.942

0.864

OD570(mean values of replicates)

0.745

0.031

0.903

Viability (%)

100

4

121

Applicant's summary and conclusion

Interpretation of results:
other: CLP/GHS criteria not met; no classification required according to Regulation (EC) No. 1272/2008
Conclusions:
CLP: not classified