Registration Dossier

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016-12-22 – 2016-12-22
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Principles of method if other than guideline:
The flow of test item under gravity through a capillary using Redwood Viscometer No. 1
GLP compliance:
not specified
Type of method:
capillary viscometer (static)
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
16.79
Remarks on result:
other: Kinematic viscosity (experimental)
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
12.75
Remarks on result:
other: Kinematic viscosity (experimental)
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
17.89
Remarks on result:
other: Dynamic viscosity (calculated)
Temp.:
40°C
Parameter:
dynamic viscosity (in mPa s)
Value:
13.59
Remarks on result:
other: Dynamic viscosity (calculated)
Conclusions:
Kinematic viscosity (experimental) of test item at 20°C and 40°C is 16.79mm²/secand 12.75mm²/s,respectively. Dynamic viscosity (calculated) of test item at 20°C and 40°C is 17.89 mPa.Sand 13.59mPa.S, respectively.
Executive summary:

Kinematic viscosity (experimental) of test item at 20°C and 40°C is 16.79mm²/secand 12.75mm²/s,respectively. Dynamic viscosity (calculated) of test item at 20°C and 40°C is 17.89mPa.Sand 13.59mPa.S, respectively.

Description of key information

Kinematic viscosity (experimental) of test item at 20°C and 40°C is 16.79mm²/secand 12.75mm²/s,respectively. Dynamic viscosity (calculated) of test item at 20°C and 40°C is 17.89mPa.Sand 13.59mPa.S, respectively.

Key value for chemical safety assessment

Viscosity:
16.79 mm²/s (static)
at the temperature of:
20 °C

Additional information

Kinematic viscosity (experimental) of test item at 20°C and 40°C is 16.79mm²/secand 12.75mm²/s,respectively. Dynamic viscosity (calculated) of test item at 20°C and 40°C is 17.89mPa.Sand 13.59mPa.S, respectively.