Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 947-664-6 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Endpoint summary
Administrative data
Description of key information
- Skin irritation/corrosion: irritating (OECD 439 and OECD 431 , GLP, Rel. 1)
- Eye irritation:not classified (OECD TG 492, GLP, Rel. 1)
Key value for chemical safety assessment
Skin irritation / corrosion
Link to relevant study records
- Endpoint:
- skin corrosion: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- December 2017 - February 2018
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 431 (In Vitro Skin Corrosion: Reconstructed Human Epidermis (RHE) Test Method)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method B.40 (In Vitro Skin Corrosion: Transcutaneous Electrical Resistance Test (TER))
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- Date: 27 April 2017
- Specific details on test material used for the study:
- TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- the test material was used as supplied - Test system:
- human skin model
- Source species:
- other: reconstituted epidermis
- Cell type:
- other: reconstituted epidermis (epiCS®, CellSystems®)
- Details on test system:
- RECONSTRUCTED HUMAN EPIDERMIS (RHE) TISSUE
- Model used: 0.60 cm2 reconstituted epidermis (epiCS®)
EXPOSURE
- The test item was applied, as supplied, at the dose of 50 µL to 2 living and 4 killed Human skin model surfaces during 3 minutes at room temperature and during 1 hour at 37°C ± 1°C, 5% ± 1% CO2.
Additionally, 2 living and 4 killed Human skin model surfaces (epiCS®, CellSystems®) were treated in the same manner during both 3 minutes and 1 hour, but they were incubated in MTT assay medium instead of MTT solution in order to generate non-specific living and killed colour controls.
- In the same experimental conditions, a positive control and a negative control were carried out.
REMOVAL OF TEST MATERIAL AND CONTROLS
- 3 minutes and 1 hour after the test item application, the human epidermis was washed 20 times with 20 mL of DPBS.
MTT DYE USED TO MEASURE TISSUE VIABILITY AFTER TREATMENT / EXPOSURE
The cell viability is quantified by measurement of the cellular mitochondrial dehydrogenases activity. These enzymes are responsible for the MTT [3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide, Thiazolyl blue; EINECS number 206-069-5, CAS number 298-93-1)] reduction into blue formazan in the viable cells. The skin sample is placed in MTT solution of appropriate concentration (e.g. 0.3 or 1 mg/mL) for 3 hours and 3 minutes between 36.4°C and 37.9°C. The precipitated blue formazan product is then extracted using a solvent (e.g. isopropanol), and the concentration of formazan is measured by determining the Optical Density (OD) at a wavelength between 540 and 600 nm (preferably 570 nm). The measured absorbances are proportional to the number of living cells.
The measurement of OD was performed using the ELx800 absorbance microplate reader supplied by BioTek and the validated software Gens ELISA V1.05.11 supplied by BioTek.
NUMBER OF REPLICATE TISSUES:
Duplicate skin tissues for test item, negative and positive controls
VIABILITY
Viability = (OD test item / OD negative control) x 100
As the test item is identified as producing both direct MTT reduction and colour interference:
True viability % = [(OD of living tissues exposed to test item - OD of killed tissues exposed to test item - OD of living tissues exposed to test item incubated with medium without MTT + OD of killed tissues exposed to test item incubated with medium without MTT) / OD of living tissues exposed to negative control] x 100
Results for test items producing non specific MTT reduction (%NSMTT) and/or non specific colour (%NSCliving) ≥ 50% of the negative control should be taken with caution.
For each tissue, OD values and calculated percentage cell viability data for the test item, positive and negative controls, should be reported in tabular form, including data from replicate repeat experiments as appropriate, mean and individual values. - Control samples:
- yes, concurrent negative control
- yes, concurrent positive control
- Amount/concentration applied:
- TEST MATERIAL
- Amount(s) applied (volume or weight with unit): 50 µL
- Concentration (if solution): Undiluted - Duration of treatment / exposure:
- 3 minutes and 1 hour
- Number of replicates:
- Duplicate skin tissues for test item, negative and positive controls
- Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- mean at 3 minutes
- Value:
- 128.16
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- mean at 1 hour
- Value:
- 100.07
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Other effects / acceptance of results:
- VIABILITY
- 3 minutes and 1 hour after the test item application, the mean percent viability of the epidermis skins treated with the test item were 128.16% and 100.07%, respectively. - Interpretation of results:
- other: test item does not have to be classified in Category 1 “Corrosive”
- Conclusions:
- Under the test conditions, in accordance with the Regulation (EC) No. 1272/2008, the results obtained enable to conclude that the test item does not have to be classified in Category 1 “Corrosive”. No hazard statement or signal word are required.
- Executive summary:
An in vitro skin corrosion study was performed according to OECD Guideline 431 and in compliance with GLP to evaluate the possible corrosive effects of the test item after topical administration on in vitro human reconstituted epidermis (epiCS®, CellSystems®).
The test item was applied as supplied, at the dose of 50 μL, to 2 living Human skin model surfaces (epiCS®, CellSystems®) during 3 minutes and 1 hour, followed by a rinse with 20 mL of DPBS. Cell viability was then measured by enzymatic conversion of the vital dye MTT into a blue formazan salt that was quantitatively measured after extraction from tissues.
3 minutes and 1 hour after the test item application, the mean percent viability of the epidermis skins treated with the test item were 128.16% and 100.7% versus 20.26% and 0.00%, respectively, with the positive control item (potassium hydroxide 8N).
Under the test conditions, in accordance with the Regulation (EC) No. 1272/2008, the results obtained enable to conclude that the test item does not have to be classified in Category 1 “Corrosive”. No hazard statement or signal word are required.
- Endpoint:
- skin irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- November 2017 - February 2018
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 439 (In Vitro Skin Irritation: Reconstructed Human Epidermis Test Method)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method B.46 (In Vitro Skin Irritation: Reconstructed Human Epidermis Model Test)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- Date: 27 April 2017
- Specific details on test material used for the study:
- TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: Used as supplied - Test system:
- human skin model
- Source species:
- other: reconstructed epidermises
- Cell type:
- non-transformed keratinocytes
- Cell source:
- other: foreskin
- Vehicle:
- unchanged (no vehicle)
- Control samples:
- yes, concurrent negative control
- yes, concurrent positive control
- Amount/concentration applied:
- TEST MATERIAL
- Amount(s) applied (volume or weight with unit): 16 µL
- Concentration (if solution): Undiluted - Duration of treatment / exposure:
- 42 minutes at room temperature
- Duration of post-treatment incubation (if applicable):
- 41 hours and 50 minutes at 37 °C,
- Number of replicates:
- 3 living human skin models
- Details on study design:
- RECONSTRUCTED HUMAN EPIDERMIS (RHE) TISSUE
- 0.50 cm² reconstructed epidermis (Episkin SA, RHE/S/17) were received, and on the same day, the insert (filter + epidermis) was gently removed from the agarose while avoiding leaving agarose on the polycarbonate filter. The inserts were placed in 6 wells culture plate which had been previously filled with 1 mL of growth medium (Episkin SA) during 2 hours and 05 minutes. Then just before treatment, the inserts were placed in 24 wells culture plate which had been previously filled with 300 µL of maintenance medium (Episkin SA).
TREATMENT
- The test item was applied as supplied, at the approximate dose of 16 µL, on the epidermal surface of 3 living human skin models during 42 minutes at room temperature.
Additionally, 2 killed Human skin model surfaces were treated (SkinEthic RHE® model) in the same manner in order to generate non-specific MTT reduction. Moreover, 2 living and 2 killed Human skin model surfaces were treated in the same manner but they were incubated in culture medium instead of MTT solution in order to generate non-specific living and killed colour controls
- In the same experimental conditions, a positive control (5% SDS) and a negative control (DPBS) were carried out. The 5% SDS solution was prepared by weighing 0.5 g of SDS in a 10 mL volumetric flask qsp 10 mL of distilled water. Then, the preparation was magnetically stirred, just before the treatment. To ensure a good contact with the epidermises, during all the treatment period, the test item was recovered with a nylon mesh provided by Episkin SA.
REMOVAL OF TEST MATERIAL AND CONTROLS
- 42 minutes after the test item application, the human epidermises were washed with 25 x 1 mL of DPBS. The rinsed tissues were checked for any coloration and noted to be slightly brown instead of being whitish as for the coloration of the negative control tissues. Residual test item with brown coloration was noted on all Reconstructed Human epidermis after the rinse. They were incubated for a 41 hours and 50 minutes post-treatment incubation period in fresh medium between at 37 °C, 5% CO2. Then, the epidermises were put in contact with the MTT solution.
MTT DYE USED TO MEASURE TISSUE VIABILITY AFTER TREATMENT / EXPOSURE
- The cell viability was quantified by the measurement of the cell succinate dehydrogenase activity. This enzyme was responsible for the MTT [3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide, Thiazolyl blue; CAS No. 298-93-1)] reduction into blue formazan crystal that is quantitatively measured by Optical Density (OD) after extraction from tissues. The measured OD were proportional to the number of living cells.
- The skin samples were placed in 300 µL of a MTT solution at 1.0 mg/mL for 3 hours at 37 °C, 5% CO2 except for the 2 living and 2 killed Human skin model surfaces for the non-specific colour
control which were placed in the maintenance medium. The precipitated blue formazan product was then extracted using isopropanol during 2 hours under gentle agitation in the dark, and the concentration of formazan was measured by determining the OD (Optical Density) at 570 nm, just after dilution of the extracts (1:2 in isopropanol).
- The OD of MTT extract was measured in triplicate. The measurement of OD was performed using the ELx800 absorbance microplate reader (controlled every year and calibrated if necessary) supplied by BioTek and the validated software Gen5 ELISA V1.05.11 supplied by BioTek.
VIABILITY CALCULATION:
- The results were expressed as a viability percentage compared with the negative control: viability % = (mean OD test item / mean OD negative control) * 100
As the test item is identified as producing both direct MTT reduction and colour interference:
True viability % = [(OD of living tissues exposed to test item - OD of killed tissues exposed to test item - OD of living tissues exposed to test item incubated with medium without MTT + OD of killed tissues exposed to test item incubated with medium without MTT) / OD of living tissues exposed to negative control] x 100
Results for test items producing non specific MTT reduction (%NSMTT) and/or non specific colour (%NSCliving) ≥ 50% of the negative control should be taken with caution.
- Data from individual replicate tissues (OD values and calculated percent tissue viability data for the test item and controls), mean percent tissue viability and standard deviation for each individual test item and control were reported in Table 7.3.1/1.
PREDICTION MODEL / DECISION CRITERIA
The OD values obtained for each test sample were used to calculate a percentage of viability relative to the negative control, which was arbitrarily set at 100%. The cut-off values for the prediction of irritation associated with the RHE models were as follows:
- The test item is considered to be non-irritant to skin if the tissue viability after 42 minutes of exposure and 42 hours of post-treatment incubation is >50%.
- The test item is considered to be irritant to skin if the tissue viability after 42 minutes of exposure and 42 hours of post-treatment incubation is ≤ 50% and the result of a skin corrosion test is "non-corrosive". In accordance with Regulation EC No. 1272/2008, the test item has to be classified in Category 2 “Irritant”. The corresponding hazard statement is “H315: Causes skin irritation” with the signal word “Warning”.
- The test item is considered to be irritant or corrosive to skin if the mean percent tissue viability after 42 minutes exposure and 42 hours of post-treatment incubation is ≤50% and in absence of information on a skin corrosion test. In accordance with the Regulation (CE) No.1272/2008 and in absence of information on a skin corrosion test, the item has to be classified in Category 2 "Irritant" or in Category 1 "Corrosive". The corresponding hazard statement is respectively, "H315: Causes skin irritation" with the signal word "Warning" or "H314: Causes severe skin burns and eye damage" with the signal word "Danger". - Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- mean corrected
- Value:
- 0.1
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Other effects / acceptance of results:
- MTT VIABILITY ASSAY RESULTS
- The mean percent viability of the treated tissues was 0.1%, versus 1.2% in the positive control (5% Sodium Dodecyl Sulfate). - Interpretation of results:
- other: Category 2 (irritating to skin) or Category 1 (corrosive) based on GHS criteria
- Conclusions:
- Under the test conditions and in accordance with Regulation EC No. 1272/2008 and in absence of information on skin corrosion, the test item has to be classified in Category 2 "Irritating to skin" or in Category 1 "Corrosive". The hazard statement "H315: Causes skin irritation" with the signal word "Warning" or "H314: Causes severe skin burns and eye damage" with the signal word "Danger" are required.
- Executive summary:
An in vitro skin irritation test using the Reconstructed Human Epidermis (SkinEthic RHE® model) was performed according to the OECD Guideline 439 and in compliance with GLP to predict the acute skin irritation potential of the test item.
The test item was applied as supplied, at the dose of 16 μL, to 3 living Reconstructed Human epidermis (SkinEthic RHE® model) during 42 minutes, followed by a rinse with 25 mL of PBS and a 41 hours and 50 minutes post-incubation period at 37°C, 5% CO2. Cell viability was then measured by enzymatic conversion of the vital dye MTT into a blue formazan salt that was quantitatively measured after extraction from tissues.
The mean percent viability of the treated tissues was 0.1%, versus 1.2% in the positive control (5% Sodium Dodecyl Sulfate).
Under the test conditions and in accordance with Regulation EC No. 1272/2008 and in absence of information on skin corrosion, the test item has to be classified in Category 2 "Irritating to skin" or in Category 1 "Corrosive". The hazard statement "H315: Causes skin irritation" with the signal word "Warning" or "H314: Causes severe skin burns and eye damage" with the signal word "Danger" are required.
Referenceopen allclose all
Table 7.3.1/1: Skin corrosion assay: Results at 3 minutes
|
Skin |
OD |
Mean OD / disc(#) |
Mean OD / product |
Viability % |
Meanviability % |
Viability difference between replicates % |
Negativecontrol |
1 |
0.524 0.591 0.618 |
0.578 |
0.570 |
101.40 |
100.00 |
2.8 |
2 |
0.608 0.558 0.521 |
0.562 |
98.60 |
||||
Positive control |
3 |
0.053 0.045 0.040 |
0.046 |
0.116 |
8.07 |
20.26 |
24.4 |
4 |
0.215 0.178 0.162 |
0.185 |
32.46 |
||||
Test item PH-17/0609 |
5 |
0.832 0.690 0.686 |
0.736 |
0.745 |
129.12 |
130.70 |
3.2 |
6 |
0.672 0.923 0.668 |
0.754 |
132.28 |
||||
Test item PH-17/0609NSMTT |
7 |
0.020 0.018 0.016 |
0.018 |
0.016 |
3.16 |
2.72 |
0.9 |
8 |
0.013 0.013 0.013 |
0.013 |
2.28 |
||||
Test item PH-17/0609 NSC livingcontrol |
11 |
0.004 0.004 0.004 |
0.004 |
0.004 |
0.70 |
0.70 |
0.0 |
12 |
0.005 0.004 0.003 |
0.004 |
0.70 |
||||
Test item PH-17/0609 NSC killedcontrol |
9 |
0.003 0.003 0.003 |
0.003 |
0.005 |
0.53 |
0.88 |
0.7 |
10 |
0.008 0.007 0.006 |
0.007 |
1.23 |
||||
Test item PH-17/0609 corrected |
|
128.16 |
|
Table 7.3.1/1: Skin corrosion assay: Results at 1 hour
|
Skin |
OD |
Mean OD / disc(#) |
Mean OD / product |
Viability % |
Mean viability % |
Viability difference between replicates % |
Negativecontrol |
1 (Plate 2) |
0.672 0.802 0.841 |
0.772 |
0.688 |
112.21 |
100.00 |
24.4 |
2 (Plate 2) |
0.603 0.622 0.587 |
0.604 |
87.79 |
||||
Positivecontrol |
3 (Plate 2) |
0.002 0.001 0.000 |
0.001 |
0.000 |
0.15 |
0.00 |
0.3 |
4 (Plate 2) |
-0.001 -0.001 -0.001 |
-0.001 |
-0.15 |
||||
Test itemPH-17/0609 |
5 (Plate 2) |
0.852 0.722 0.706 |
0.760 |
0.716 |
110.47 |
104.07 |
12.8 |
6 (Plate 2) |
0.720 0.648 0.647 |
0.672 |
97.67 |
||||
Test itemPH-17/0609NSMTT |
7 (Plate 2) |
0.012 0.009 0.009 |
0.010 |
0.020 |
1.45 |
2.83 |
2.8 |
8 (Plate 2) |
0.032 0.027 0.028 |
0.029 |
4.22 |
||||
Test itemPH-17/0609 NSC livingcontrol |
11 (Plate 2) |
0.009 0.008 0.008 |
0.009 |
0.010 |
1.31 |
1.38 |
0.1 |
12 (Plate 2) |
0.011 0.008 0.010 |
0.010 |
1.45 |
||||
Test itemPH-17/0609 NSC killedcontrol |
9 (Plate 2) |
0.000 0.000 0.000 |
0.000 |
0.002 |
0.00 |
0.22 |
0.4 |
10 (Plate 2) |
0.004 0.002 0.001 |
0.003 |
0.44 |
||||
Test itemPH-17/0609 corrected |
|
100.07 |
|
#: mean of 3 values
OD: optical density
Table 7.3.1/1: Main test - Individual and mean OD values and tissue viabilities for the test item, the negative and positive controls
|
Skin |
OD |
Mean OD / disc(#) |
Mean OD / product |
Viability % |
Mean viability % |
SD |
|
|
0.958 |
|
|
|
|
|
|
1 |
1.129 |
1.073 |
|
107.2 |
|
|
|
|
1.133 |
|
|
|
|
|
Negativecontrol |
2 |
1.009 1.018 1.052 |
1.026 |
1.001 |
102.5 |
100.0 |
8.7 |
|
|
0.885 |
|
|
|
|
|
|
3 |
0.912 |
0.904 |
|
90.3 |
|
|
|
|
0.917 |
|
|
|
|
|
|
|
0.010 |
|
|
|
|
|
|
4 |
0.011 |
0.010 |
|
1.0 |
|
|
|
|
0.011 |
|
|
|
|
|
Positivecontrol |
5 |
0.011 0.011 0.011 |
0.011 |
0.012 |
1.1 |
1.2 |
0.2 |
|
|
0.014 |
|
|
|
|
|
|
6 |
0.015 |
0.014 |
|
1.4 |
|
|
|
|
0.014 |
|
|
|
|
|
|
|
0.022 |
|
|
|
|
|
|
16 |
0.023 |
0.023 |
|
2.3 |
|
|
|
|
0.024 |
|
|
|
|
|
Test itemPH-17/0609 |
17 |
0.022 0.021 0.025 |
0.022 |
0.022 |
2.2 |
2.2 |
0.1 |
|
|
0.020 |
|
|
|
|
|
|
18 |
0.021 |
0.021 |
|
2.1 |
|
|
|
|
0.022 |
|
|
|
|
|
Test itemPH-17/0609 NSC Control living tissues |
22 |
0.003 0.004 0.003 |
0.003 |
0.003 |
0.3 |
0.2 |
0.1 |
23 |
0.003 0.002 |
0.002 |
0.2 |
||||
|
|
0.002 |
|
|
|
|
|
Test itemPH-17/0609 NSC Control killed tissues |
24 |
0.001 0.002 0.002 |
0.001 |
0.002 |
0.1 |
0.1 |
0.1 |
25 |
0.002 0.002 |
0.002 |
0.2 |
||||
|
|
0.003 |
|
|
|
|
|
Test itemPH-17/0609 killed tissues MTT control |
26 |
0.025 0.027 0.018 |
0.023 |
0.020 |
2.3 |
1.9 |
0.5 |
27 |
0.017 0.017 |
0.016 |
1.6 |
||||
|
|
0.016 |
|
|
|
|
|
Test item PH-17/0609 corrected |
|
0.1 |
|
#: mean of 3 values (triplicate of the same extract) OD: optical density
Endpoint conclusion
- Endpoint conclusion:
- adverse effect observed (irritating)
Eye irritation
Link to relevant study records
- Endpoint:
- eye irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- November 2017- february 2018
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 492 (Reconstructed Human Cornea-like Epithelium (RhCE) Test Method for Identifying Chemicals Not Requiring Classification and Labelling for Eye Irritation or Serious Eye Damage)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- Date: 27 April 2017
- Specific details on test material used for the study:
- TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- The test item was used as supplied in the study - Species:
- other: Reconstructed human Cornea-like Epithelia
- Details on test animals or tissues and environmental conditions:
- - Description of the cell system used: 0.60 cm² Reconstructed human Cornea-like Epithelia [EpiOcular(TM) OCL-212-ver2.0, supplied by MatTek Corporation]
- Vehicle:
- unchanged (no vehicle)
- Controls:
- yes, concurrent positive control
- yes, concurrent negative control
- Amount / concentration applied:
- TEST MATERIAL
- Amount(s) applied (volume or weight with unit): 50 µL
- Concentration: Undiluted - Duration of treatment / exposure:
- 30 minutes at 37°C, 5% CO2, 95% humidity (standard culture conditions)
- Duration of post- treatment incubation (in vitro):
- - Post-exposure immersion period: 12 minutes at room temperature
- Post-exposure incubation period: 2 hours at standard culture conditions - Number of animals or in vitro replicates:
- Test item, negative and positive controls were applied on duplicate tissues.
- Details on study design:
- MAIN TEST
- Pre-incubation of the tissues:
On the day of receipt, the 12 tissues in their 24-well shipping container were equilibrated at room temperature for 15 minutes. Then the inserts (filter + epithelium) were gently removed from the agarose while avoiding leaving agarose on the polycarbonate filter. They were placed in 6 wells culture plate which had been previously filled with 1 mL of 37°C pre-warmed assay medium and incubated during 19 hours and 45 minutes at standard culture conditions.
After the overnight incubation, the tissues were pre-wetted with 20 μL of Ca2+Mg2+Free-DPBS. The tissues were incubated at standard culture conditions for 30 minutes.
- Treatment and post-treatment incubation of the tissues:
The test item was applied (50 µL) to 2 living RhCE (EpiOcularTM tissue model) during 30 minutes at 37°C, 5% CO2, 95% humidity (standard culture conditions). In the same experimental conditions, a positive control (Methyl acetate), and a negative control (distilled water) were used. The controls were applied, as supplied, at the dose of 50 µL, to the surface of 2 viable RhCE tissue replicates during 30 minutes at standard culture conditions. Additionally, 2 killed RhCE (EpiOcularTM tissue model) were treated in the same manner in order to generate non-specific MTT reduction. Moreover, 2 living and 2 killed RhCE tissue replicates were treated in the same manner in order to generate non-specific living and killed colour controls
After the treatment, the test item and control substances were carefully washed from the RhCE tissues by extensive rinsing with Ca2+Mg2+Free-DPBS. The rinsed tissues were checked for any colouration and noted for comparable colour with the negative control. This rinsing step was followed by a 12-minute post-exposure immersion period at room temperature in 5 mL of fresh medium to remove any test item absorbed into the tissue. The RhCE constructs were then incubated for a 2-hour post-exposure incubation at standard culture conditions in 1 mL of fresh medium at 37°C, 5% CO2.
- MTT viability assay:
Following the exposure to the test item, viability measurements are performed immediately after the post-exposure incubation period of the rinsed tissues in fresh medium. This period allows both for recovery from weak cytotoxic effects and for appearance of clear cytotoxic effects.
The RhCE tissue viability was measured by enzymatic conversion of the vital dye MTT [3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide; Thiazolyl blue tetrazolium bromide; CAS No. 298-93-1] by the viable cells of the tissue into a blue MTT formazan salt that is quantitatively measured by Optical Density (OD) after extraction from tissues. The measured OD was proportional to the number of living cells.
The RhCE constructs were placed in 300 µL of a MTT solution at 1.0 mg/mL for 3 hours at standard culture conditions except for the non-specific colour controls which were incubated in assay medium. The precipitated blue formazan product was then extracted from the tissues by placing each insert in 2 mL of isopropanol during 17 hours and 20 minutes at 6±3°C in the dark. The concentration of formazan was measured by determining the OD at 570 nm, just after dilution of the extractions in isopropanol (1:2). The OD measurement of formazan extracts at 570 nm was measured in triplicate samples using the ELx800 absorbance microplate reader (controlled every year and calibrated if necessary) supplied by BioTek and the validated software Gen5 ELISA V1.05.11 supplied by BioTek. - Irritation parameter:
- other: mean viability % (corrected)
- Value:
- 90.53
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Other effects / acceptance of results:
- MAIN TEST
- MTT assay results: The mean percent tissue viability of the RhCE replicates treated with the test substance was 90.53% versus 44.19% in the positive control (Methyl acetate). Refer Tables 7.3.2/1 for more details. - Interpretation of results:
- GHS criteria not met
- Conclusions:
- Under the test conditions and in accordance with Regulation EC No. 1272/2008, the test substance was not identified as potentially requiring classification and labelling according to UN GHS (Category 2 or Category 1).
- Executive summary:
An in vitro eye irritation test using the Reconstructed human Cornea-like Epithelium (RhCE) (EpiOcular™ tissue) model was performed according to the OECD Guideline 492 and in compliance with GLP to predict the acute eye irritation potential of the test substance.
The test substance (50 µL) was applied to two RhCE (EpiOcular™ tissue model) during 30 minutes at 37°C, 5% CO2, 95% humidity (standard culture conditions). The exposure period was followed by extensive rinsing with PBS at room temperature, a 12-minute post-exposure immersion period at room temperature and a 2-hour post-exposure incubation at standard culture conditions. The tissue viability was measured by performing a MTT assay.
The mean percent tissue viability of the RhCE replicates treated with the test substance was 90.53% versus 44.19% in the positive control (Methyl acetate).
Under the test conditions and in accordance with Regulation EC No. 1272/2008, the test substance was not identified as potentially requiring classification and labelling according to UN GHS (Category 2 or Category 1).
Reference
Table 7.3.2/1: Main test - Individual and mean corrected OD values and tissue viabilities for the test item, the negative and positive controls
|
Skin |
OD |
Mean OD / disc(#) |
Mean OD / product |
Viability % |
Mean viability % |
Difference of viability % |
Negative control |
1 |
0.829 0.861 0.857 |
0.849 |
0.861 |
98.61 |
100.00 |
2.8 |
2 |
0.889 0.909 0.822 |
0.873 |
101.39 |
||||
Positive control |
3 |
0.356 0.333 0.350 |
0.346 |
0.381 |
40.19 |
44.19 |
8.0 |
4 |
0.463 0.404 0.380 |
0.415 |
48.20 |
||||
Test item PH-17/0609 |
5 |
0.753 0.793 0.880 |
0.808 |
0.826 |
93.84 |
95.88 |
4.1 |
6 |
0.856 0.864 0.811 |
0.843 |
97.91 |
||||
Test item PH-17/0609 NSMTT |
5 |
0.052 0.055 0.059 |
0.056 |
0.049 |
6.50 |
5.69 |
1.6 |
6 |
0.045 0.039 0.040 |
0.042 |
4.88 |
||||
Test item PH-17/0609 NSC living control |
1 |
0.010 0.011 0.011 |
0.011 |
0.012 |
1.28 |
1.39 |
0.2 |
2 |
0.014 0.012 0.013 |
0.013 |
1.51 |
||||
Test item PH-17/0609 NSC killed control |
3 |
0.011 0.010 0.008 |
0.010 |
0.015 |
1.16 |
1.74 |
1.2 |
4 |
0.021 0.022 0.017 |
0.020 |
2.32 |
||||
Test item PH-17/0609 corrected |
|
90.53 |
|
#: mean of 3 values (triplicate of the same extract)
OD: optical density
Endpoint conclusion
- Endpoint conclusion:
- no adverse effect observed (not irritating)
Respiratory irritation
Endpoint conclusion
- Endpoint conclusion:
- no study available
Additional information
Skin irritation:
An in vitro skin irritation test using the Reconstructed Human Epidermis (SkinEthic RHE® model) was performed according to the OECD Guideline 439 and in compliance with GLP to predict the acute skin irritation potential of the test item.
The test item was applied as supplied, at the dose of 16 μL, to 3 living Reconstructed Human epidermis (SkinEthic RHE® model) during 42 minutes, followed by a rinse with 25 mL of PBS and a 41 hours and 50 minutes post-incubation period at 37°C, 5% CO2. Cell viability was then measured by enzymatic conversion of the vital dye MTT into a blue formazan salt that was quantitatively measured after extraction from tissues.
The mean percent viability of the treated tissues was 0.1%, versus 1.2% in the positive control (5% Sodium Dodecyl Sulfate).
Skin corrosion:
An in vitro skin corrosion study was performed according to OECD Guideline 431 and in compliance with GLP to evaluate the possible corrosive effects of the test item after topical administration on in vitro human reconstituted epidermis (epiCS®, CellSystems®).
The test item was applied as supplied, at the dose of 50 μL, to 2 living Human skin model surfaces (epiCS®, CellSystems®) during 3 minutes and 1 hour, followed by a rinse with 20 mL of DPBS. Cell viability was then measured by enzymatic conversion of the vital dye MTT into a blue formazan salt that was quantitatively measured after extraction from tissues.
3 minutes and 1 hour after the test item application, the mean percent viability of the epidermis skins treated with the test item were 128.16% and 100.7% versus 20.26% and 0.00%, respectively, with the positive control item (potassium hydroxide 8N).
Eye irritation:
An in vitro eye irritation test using the Reconstructed human Cornea-like Epithelium (RhCE) (EpiOcular™ tissue) model was performed according to the OECD Guideline 492 and in compliance with GLP to predict the acute eye irritation potential of the test substance.
The test substance (50 µL) was applied to two RhCE (EpiOcular™ tissue model) during 30 minutes at 37°C, 5% CO2, 95% humidity (standard culture conditions). The exposure period was followed by extensive rinsing with PBS at room temperature, a 12-minute post-exposure immersion period at room temperature and a 2-hour post-exposure incubation at standard culture conditions. The tissue viability was measured by performing a MTT assay.
The mean percent tissue viability of the RhCE replicates treated with the test substance was 90.53% versus 44.19% in the positive control (Methyl acetate).
Justification for classification or non-classification
Self - classification :
According to results from OECD 439 and OECD 431 study, the registered substance is classified as category 2 for skin irritation (H315) according to Regulation EC N° 1272/2008 (CLP) and GHS.
According to the results of OECD TG 492, the registered substance should not be classified according to Regulation EC N° 1272/2008 (CLP) and GHS.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.