Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
07 Dec 2007
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report date:
2007

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ASTM D3278 (Standard test methods for flash point of liquids by small scale closed-cup apparatus)
Deviations:
yes
Remarks:
Sample was provided in a non-ASTM compliant container less than 90% full.
GLP compliance:
no
Remarks:
Test predates requirement for GLP compliance
Type of method:
closed cup

Test material

Constituent 1
Chemical structure
Reference substance name:
1,1,3-trihydro-4,8-dioxaperfluorononanol
Cas Number:
958445-53-9
Molecular formula:
C7H4F12O3
IUPAC Name:
1,1,3-trihydro-4,8-dioxaperfluorononanol
Test material form:
liquid

Results and discussion

Flash point
Key result
Flash point:
> 93 °C
Atm. press.:
735.4 mm Hg
Remarks on result:
no flash point according to standard method

Any other information on results incl. tables

No flash was identified at 20, 38, 60, and 93 °C or at any intervening temperature.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
DONOL has no flash point at tested temperatures of 20, 38, 60, and 93 °C (ASTM D-3278-96).
Executive summary:

No flash point could be determined using the small scale closed cup method. The study was conducted in accordance with ASTM D3278 but was not GLP compliant. Therefore, the study is considered reliable with restrictions.