Registration Dossier

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flammable gases
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Endpoint:
flammable liquids: obsolete as covered by section 'Flash point'
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Endpoint:
pyrophoric liquids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied
Endpoint:
flammable solids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Endpoint:
self-heating substances / mixtures
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Endpoint:
substances / mixtures which in contact with water emit flammable gases
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the experience in production or handling shows that the substance does not react with water, e.g. the substance is manufactured with water or washed with water

Description of key information

Based on flash point determination according to EU Method A.9 and experience in handling and use, the test item was considered not flammable as such or in contact with water and not to exhibit pyrophoric properties. The chemical structure of the test item contains no groups associated with flammability properties (as such or in contact with water) and/or pyrophoric properties. Studies according to EU Method A.12 and EU Method A.13 were waived and a theory based evaluation provided.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

In accordance with 3rd draft ECHA guidance IR/CSA chapter R.7a table R.7.1-6, the test on the flammability (Regulation (EC) No 440/2008 method A.10) was not performed as the test item is a liquid. For liquids the primary value for ease of ignition is the flash point conducted using Method A9 ‘Flash Point Method’ of Council Regulation (EC) No 440/2008. The result of the Flash Point test is used to allocate a liquid substance into the appropriate flammability class.

In accordance with Annex XI Regulation (EC) No 1907/2006 (REACH), the test on flammability in contact with water does not need to be conducted as the substance shows no reaction with water. The chemical structure of test item does not contain chemical groups, which may lead to the conclusion that the test substance is capable of developing a dangerous amount of (flammable) gas in contact with damp air or water. This is based on the experience in handling and use.

In accordance with Annex XI Regulation (EC) No 1907/2006 (REACH), the test on pyrophoric abilities does not need to be conducted as the substance in not flammable and shows no reaction with the air.The test substance does not contain any chemical group that might lead to spontaneous ignition a short time after coming in contact with air at room temperature. This is based on the experience in handling and use.

Justification for classification or non-classification