Registration Dossier

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
05 March 2018 - 09 March 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
Qualifier:
according to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
effusion method: vapour pressure balance
Specific details on test material used for the study:
Batch: 53715080
Storage condition of test material: Room temperature in the dark
Key result
Temp.:
ca. 25 °C
Vapour pressure:
ca. 0.006 Pa
Conclusions:
The vapor pressure of the test item has been determined to be 5.9 x 10-3 Pa at 25 ºC.

Description of key information

The vapor pressure of the test item has been determined to be 5.9 x 10-3 Pa at 25 ºC.

Key value for chemical safety assessment

Vapour pressure:
0.006 Pa
at the temperature of:
25 °C

Additional information