Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
12 Dec 2006 - 22 Jan 2007
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient - HPLC Method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7570 (Partition Coefficient, n-octanol / H2O, Estimation by Liquid Chromatography)
Deviations:
no
GLP compliance:
yes
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 09898602
- Expiration date of the lot/batch: > 6 months from receipt date at 25°C
- Date received: 6 Nov 2006
- Purity: 99.8%
- Physical Appearance: yellow liquid
- Storage: refrigerated, 1-10 °C
Analytical method:
high-performance liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
1.92
Temp.:
25 °C
Remarks on result:
other: pH not stated
Details on results:
The Subject Chemical eluted as a single peak with a retention time that was within the range of retention times of the calibration substances. Therefore the results of the estimation may be expected to be realistic, because they were calculated by interpolation rather than by extrapolation. It was possible to establish the calibration line with six different calibration compounds, one eluting before the test compound, one with an almost identical retention time to the Subject Chemical itself and four eluting after it.
There were only minimal differences between the replicates of retention times for each of the calibration and test substances, and between the two injection sequences. The resultant calculated values differed only to a small extent, therefore the results may be considered as acceptable for regulatory purposes.

Statistical data
Slope 0.2570 0.2579
Intercept -0.7312 -0.7357
Correlation (r2) 0.9934 0.9937

Analytical Data
Compound Retention time mean (min) log K log Pow 95% min 95% max
First estimation 
Test Item 4.230 -0.238 1.92 1.8 2.03
  Back calculated calibration compound (Log Pow = 1.90)
Nitrobenzene 4.230 -0.238 1.92 1.8 2.03
Second estimation 
Test Item 4.220 -0.244 1.91 1.79 2.01
  Back calculated calibration compound (Log Pow = 1.90)
Nitrobenzene 4.235 -0.239 1.92 1.81 2.03
Conclusions:
The octanol: water partition coefficient of the test item was evaluated using the HPLC simulation technique.
The test substance eluted as a single component with a mean retention time corresponding to a log Pow value of 1.92.
Executive summary:

Introduction


The octanol:water partition coefficient of the Subject Chemical was evaluated using the HPLC simulation technique with a mobile phase of methanol/water, 75/25 v/v.


Results


The Subject Chemical eluted as a single peak with a retention time that was within the range of retention times of the calibration substances. Therefore the results of the estimation may be expected to be realistic, because they were calculated by interpolation rather than by extrapolation. It was possible to establish the calibration line with six different calibration compounds, one eluting before the test compound, one with an almost identical retention time to the Subject Chemical itself and four eluting after it.
There were only minimal differences between the replicates of retention times for each of the calibration and test substances, and between the two injection sequences. The resultant calculated values differed only to a small extent, therefore the results may be considered as acceptable for regulatory purposes.


Conclusion


The test substance eluted as a single component with a mean retention time corresponding to a log Pow value of 1.92.

Description of key information

The test substance eluted as a single component with a mean retention time corresponding to a log Pow value of 1.92.

Key value for chemical safety assessment

Log Kow (Log Pow):
1.92
at the temperature of:
25 °C

Additional information

The determination of partition coefficient of MEDOL-10 was carried out using the HPLC method (Covance Laboratories Limited, 2007, Study 2777/001-D2149). The procedure was designed to be compatible with the EC Method A.8, the OECD test guideline 117 and the EPA test guideline OPPS 830.7570, and was conducted in compliance with GLP.

 

The test substance eluted as a single component with a mean retention time corresponding to a log Pow value of 1.92.