Registration Dossier

Guidance on Safe Use

Guidance on Safe Use

Currently viewing:

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove patient to fresh air, seek medical advice.
Emergency measure - Eyes: Rinse immediately with plenty of water.
Emergency measure - Skin: Wash immediately with plenty of water.
Emergency measure - Ingestion: Seek medical attention.

Fire-fighting measures

Recommended extinguishing agent: Recommended extinguishing agents: Dry powder or halon type
extinguisher may be used. Avoid the use of water.

Product arising from burning: Products arising from pyrolysis: Products of combustion may
contain oxides of carbon, nitrogen together with hydrogen
chloride and some soot.

Protective equipment: Protective equipment: None recommended.

Accidental release measures

Emergency measures in case of spillage: Isolate spillage and remove personnel from the affected
area. Sweep up spill and place in a suitably labelled
container for disposal at a landfill site or by
incineration in accordance with local regulations. Avoid
discharge to waste waters.

Handling and storage

Handling: Observe the usual precautions when handling organic
chemicals. Avoid contact with skin and eyes. Protective
clothing should be worn. Avoid dust formation, wear a dust
mask if necessary.

Storage: Store in a dry place.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport: No special precautions.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: Other dangers: None reported.

Chemical reaction with water: Chemical reaction with water: None reported.

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery by recrystallisation is possible.

Industry - Possibility of neutralisation: Not applicable.

Industry - Possibility of destruction: controlled discharge: The substance can be disposed of at a suitable landfill of
class 1 containment. Disposal at a non-containment site is
not recommended as the substance is not readily
biodegradable. Discharge to controlled waters not
recommended, maximum concentration should be 10 mg/l.

Industry - Possibility of destruction - incineration: Recommended method at a suitable facility with a
temperature of approx 1200 deg C. Waste gas treatment to
remove nitrogen oxides and hydrogen chloride gas should be
fitted.

Industry - Possibility of destruction - water purification: The substance should be diluted in excess of 2.5 times the
required to ensure outlet concentrations below the no
observed effect level and inlet concentration of 25 mg/l.

Public at large - Possibility of recovery/recycling: The substance will not enter the public domain.