Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010-01-28
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002. Remark: ASTM D-93A
GLP compliance:
no
Type of method:
closed cup
Remarks:
Pensky Martens closed cup method
Flash point:
330 K
Atm. press.:
ca. 1 013 hPa
Flash point:
165.56 °C
Atm. press.:
ca. 1 013 hPa

No values given for pressure, assumed approximately 1013 hPa.

Description of key information

165.56 °C (closed cup, ASTM D-93A)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
165 °C