Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Flash point = 194 °C at 760 mm Hg, EU Method A.9, McLean 2013a

Key value for chemical safety assessment

Flash point at 101 325 Pa:
194 °C

Additional information

The flash point of the test material was determined under GLP conditions, in accordance with the standardised guideline EU Method A.9, using the closed cup method. Under the conditions of the study, the flash point of the test material was determined to be 194 °C at atmospheric pressure (760 mm Hg).

The study was performed in line with GLP and an accepted standardised guideline with a good level of reporting. The study was therefore assigned a reliability score of 1 and considered suitable for assessment as an accurate reflection of the substance.

The available data are considered to be complete and the result determined, flash point 194 °C at 760 mm Hg, was taken forward for risk assessment.