Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
18 Oct 2000
Reliability:
1 (reliable without restriction)

Data source

Referenceopen allclose all

Reference Type:
study report
Title:
Unnamed
Year:
2000
Report date:
2000
Reference Type:
other company data
Title:
Unnamed
Year:
2000
Report date:
2001

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.12 (Flammability (Contact with Water))
Deviations:
not applicable
Remarks:
Test not performed
Qualifier:
according to guideline
Guideline:
EU Method A.13 (Pyrophoric Properties of Solids and Liquids)
Deviations:
not applicable
Remarks:
Test not performed
GLP compliance:
yes

Test material

Constituent 1
Reference substance name:
MV31 K-salt
IUPAC Name:
MV31 K-salt
Details on test material:
- Name of test material (as cited in study report): MV31 K-salt
- Analytical purity: approx. 88 area %
- Storage condition of test material: At ambient temperature and dry

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Remarks on result:
other: Test substance could not be ignited
Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record. | Remarks: | Additional remarks: Test not performed - structure excludes properties
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record. | Remarks: | Additional remarks: Test not performed - structure excludes properties
Substances / mixtures which in contact with water emit flammable gases
Remarks on result:
no reaction with water observed
Remarks:
corresponding to 'no' in migrated source record.| Remarks: | Additional remarks: Test not performed - structure excludes properties

Any other information on results incl. tables

The test on evolution of highly flammable gases was not performed because a chemical reaction is not expected upon contact with water. The test substance is produced in aqueous solution. The test of pyrophoric properties was also not performed because the carbon contained in the test substance is chemically bonded to carbon, fluorine, and oxygen. The molecule contains no double bond between two carbon atoms or any chemical bond between carbon and hydrogen.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
MV31-K-salt was determined to be non-flammable.
Executive summary:

The flammability of MV31-K-salt was determined according to EU Method A.10 under GLP; therefore the study is considered reliable without restrictions. The results may be used for Classification & Labelling and Risk Assessment.