Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Eye Contact     Consult a physician.

                         Immediately rinse eyes thoroughly with running water as long as possible (approx. 15 min).

                         Take injured quickly to factory medical center or call an ambulance (code word: eye accident).

Skin Contact    If skin irritation persists, call a physician.

                         Remove contaminated clothing. Rinse contaminated skin immediately with plenty of water and

                         seek medical advice.

Inhalation        Remove the victim from danger zone, avoid further exposure.

                        Consult a physician if irritating symptoms develop and persist.

Ingestion        Clean mouth with water and drink afterwards plenty of water. Call a physician. Obtain medical advice.

Fire-fighting measures

Suitable Extinguishing Media                       Water spray or fog, foam, dry chemical powder, CO2, dry sand

Unsuitable Extinguishing Media                  High volume water jet

Protective equipment for firefighters         Wear self-contained breathing apparatus and fire protective suite.

Accidental release measures

Personal precautions             Wear chemical resistant protective suite. Minimize number of personnel in risk area. Keep away unprotected persons. Wear                                                                  chemical-proof clothes and masks while undressingcontaminated persons or cleaning contaminated equipment.

Environmental precautions   Firefighting water may not spill into open rivers and ponds. Collect spilled material by all available means. Do not release into the                                                      environment.

Methods for cleaning             Moisten spilled material with water (in order to avoid dust formation), cover with wet sand or wetted binder, then take up. Wash aw                                                   ay remains with plenty of water. Put into lead-sealable and labelled drums.

Handling and storage

Preventive Precautions (fire/explosion)    Take precautionary measures against static discharges.

Conditions of storage                                   Protect against heat

Maximum Storage Temperature (safety)    30 °C

Storage and Handling Precautions              Ensure efficient exhaust ventilation when using this product Avoid formation of dust.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Control parameters

Novartis internal Benchmark Guidance Value: <0.001 mg/m3

Industrial Hygiene    

The personal protective measure may be adapted appropriately when working in closed systems or under laboratory conditions., Regular cleaning of equipment, work area and clothing., No open handling without using reliable equipment. One technical barrier between substance and employee resp. environment., Restricted and controlled access for trained personnel only., Designated washing, changing and shower facilities must be available., Internal working procedures available to personnel covering personal hygiene, decontamination /cleaning, consideration of worst case incidents, spills, emergency, alarms, waste disposal and maintenance., Personnel comprehensively instructed, highly trained and experienced. Regular refresher training established including appropriate record keeping., Equipment and protective garments must either be decontaminated or properly contained for disposal before leaving the area., Disposable protective equipment is to be decontaminated before removal (decontamination shower)., Biological monitoring of exposure is not recommended.

Open Handling

Respiration : Full face mask (EN136)

Filter : P3 (EN143)

Eye : Yes, by face mask

Hand : Normal length chemical-mechanical-resistant gloves (EN374/EN388) worn over disposable gloves

Glove Material : Nitrile

Breakthrough time: > 480 min

Thickness: 0.2 mm

Additional protection : Disposable dust-proof suit (EN465, type 4) worn over long underwear Disposable boot covers, conductive

Stability and reactivity

Isoperibolic Decomposition (>8h)                   Stable up to: 140 °C (Air open cup)

                                                                              Method: Radex isoperibolic (long duration decomposition test open cup 8h)

                                                                              Exothermal decomposition may occur with delay (autocatalysis)

Dynamic Decomposition                                    Exothermy: 180 °C (Air open cup)

                                                                               Method: Radex dynamic decomposition test (temp.progr. 0.75°C/min, examined up to 360°C)

                                                                               Exothermy: 180 °C (air closed + stl steel)

                                                                               Decomposition energy: > 90 J/g

                                                                               Method: Radex dynamic decomposition test (temp.progr. 0.75°C/min, examined up to 360°C)

                                                                               Exothermy: 190 °C (Steel gold plated, closed (high pressure))

                                                                               Decomposition energy: 160 J/g

                                                                               Method: Radex isoperibolic (long duration decomposition test open cup 8h)

Combustibility Test                                             Standard conditions: 2 = after ignition the fire dies out rapidly (Temperature: 20 °C)

                                                                               Method: Combustibility test safety lab SCHNYDER

Dust Explosion                                                     Weak dust explosion.: Positive

                                                                               Method: SCHNYDER dust-explosion test

                                                                               Minimum Ignition Energy: 30 - 100 mJ

                                                                               Method: MIKE3i (minimal ignition energy test with inductance)

Explosivity/Reactivity                                          Deflagration: No suspect of deflagration based on thermal data

                                                                               Method: SCHNYDER deflagration test

                                                                               Drop-Weight Test: Negative

                                                                               Method: Drop-Weight Test

Hazardous Decomposition Products               Material: carbon monoxide

                                                                              Material: poisonous gases/vapors

                                                                              Material: nitrogen oxides

                                                                              Material: sulfur oxides

                                                                              Materials to avoid Material: None

Disposal considerations

Disposal Requirements                     Fill into suitable waste receptacles, seal and label them properly.

                                                             Incineration in an approved, controlled furnace with combustion gas scrubbing and emission gas control.

Container Disposal                            Can be incinerated, when in compliance with the Environment Protection.